Recall of Device Recall CystoCare Coloplast

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Nurse Assist, Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    58021
  • Event Risk Class
    Class 2
  • Event Number
    Z-2284-2011
  • Event Initiated Date
    2011-01-20
  • Event Date Posted
    2011-05-25
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-10-25
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Catheter, urological - Product Code KOD
  • Reason
    The trays contain triad group sterile lubricating jelly packs recalled by triad group because of the possibility of inadequate sterilization.
  • Action
    The firm, Nurse Assist Incorporated, sent a letter dated January 20, 2011 to its customers. The letter described the product, problem and actions to be taken. The customers were instructed to examine their inventory immediately; quarantine the product; identify their customers and notify them at once about the product recall (Nurse Assist will provide bright labels to affix to your affected inventory); provide their customers with labels as well, and complete and return the attached RECALL ACKNOWLEGEMENT form via fax to: 817-231-1500 or mail to: Nurse Assist, Inc., 3400 Northern Cross Blvd., Forth Worth, TX 76137. Only the product and lots identified on the attached list are affected. If you have any questions or to request labels, please call Nurse Assist Customer Service Monday through Friday, from 8:00 am to 5:00 pm Central Time at 1-800-649-6800.

Device

  • Model / Serial
    Lot Codes: 803131, 804053, 1001123, 1002193, 1002263, 1003050, 1003330, 1003335, 1003341, 1005002, 1005177, 1005319, 1006002, 1006069, 1006191, 1006316, 1007022, 1007371, 1008020, 1008196, 1008269, 1009018, 1009071, 1009176, 1009384, 1010207, 1011077, 1011115, 1011337, 806071, 806206, 806275, 809278, 811067, 812042, 812216, 901112, 901128, 901207, 902048, 902240, 903161, 903222, 903328, 904043, 904351, 905074, 905180, 905239, 906032, 906035, 906318, 906323, 907225, 908266, 909171, 909267, 909322, 910003, 910218, 910406, 911072, 911273, 912151, and 912358.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide distribution: USA (nationwide) and countries including: Canada, Dubai and Saudi Arabia.
  • Product Description
    Case Label: REF UT7015 Catheter Insertion Tray 10cc Pre-Filled Syringe with BZK Swabs Qty: 20 For Rx Only Sterile unless package is damaged or opened. Latex Free STERILE EO Distributed by: Coloplast Corp. Minneapolis, MN 55411 USA 1-800-328-3863 Manufactured for: Coloplast A/S 3050 Denmark || Tray Label: Cysto-Care Coloplast REF: UT7015 Catheter Insertion Tray 10 cc Pre-Filled Syringe with BZK Swabs contents 1200 cc graduated drainage tray Waterproof underpad Fenestrated drape Vinyl gloves (2) cuffed Lubricating jelly Specimen container with ID label 10 cc pre-filled syringe Swabsticks (3) BZK solution For Rx Only. Sterile unless package is damaged or opened. Latex Free Manufactured for: Coloplast A/S 3050 Denmark Distributed by: Coloplast Corp. Minneapolis, MN 55411 USA 1-800-328-3863 STERILE EO Assembled in USA || Intended use: The trays are urological catheter trays.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Nurse Assist, Inc, 3400 Northern Cross Blvd, Fort Worth TX 76137-3600
  • Manufacturer Parent Company (2017)
  • Source
    USFDA