Recall of Device Recall Coyote MONORAIL PTA Balloon Dilatation Catheter

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Boston Scientific Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    67437
  • Event Risk Class
    Class 2
  • Event Number
    Z-0971-2014
  • Event Initiated Date
    2014-02-04
  • Event Date Posted
    2014-02-11
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2014-08-04
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Catheter, angioplasty, peripheral, transluminal - Product Code LIT
  • Reason
    Boston scientific is initiating this recall removal of one lot of the coyote" over-the-wire pta balloon dilatation catheter and one lot of the coyote" monorail" pta balloon dilatation catheter. boston scientific has become aware that the balloons of the devices from these lots may not deflate as expected during a procedure. to date, boston scientific has received three complaints for this issue. t.
  • Action
    Consignees were sent a Boston Scientific " Urgent Medical Device Recall Removal" letter on 2/4/2014. The letter was addressed to Materials Manager and Field Action Contact. The letter described the product involved in the recall and the problem. Advised consignees to segregate the affected lots and return to Boston Scientific in accordance to the enclosed recall instructions. The instructions also requested consignees to complete and return the Account Reply Verification Tracking Form (RVTF).

Device

  • Model / Serial
    16310947
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    US: AL, CA, FL, IL, IN, MI, MO, NY, OH, PA, TX. OUS: ITALY, GERMANY, FRANCE, GREAT BRITAIN, NETHERLANDS, WHITE RUSSIA, INDIA, JAPAN.
  • Product Description
    Boston Scientific, Coyote" MONORAIL" PTA Balloon Dilatation Catheter, UPN # H74939185201510, Catalogue # 39185-20151.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Boston Scientific Corporation, 1 Scimed Pl, Maple Grove MN 55311-1565
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “We take a patient-first approach to assessing the applicability of every recall and communicate to regulatory bodies in all geographies where the recalled device is sold,” Boston Scientific said in a statement to ICIJ. “We have coordinated several recalls across many countries in a timely manner,” the company said, adding that it complies with all national laws, which can often vary and require different processes for reporting information or taking action on recalls. The company said it uses a rigorous and uniform process to take action on recalls and that “when we initiate a field action (e.g. recall, safety alert), every customer who has received an affected product receives a communication that includes a letter for the physician.”
  • Source
    USFDA