Recall of Device Recall cortical bone screw

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Acumed LLC.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    55184
  • Event Risk Class
    Class 2
  • Event Number
    Z-1602-2010
  • Event Initiated Date
    2009-05-19
  • Event Date Posted
    2010-05-14
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2010-05-17
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Screw, fixation, bone - Product Code HWC
  • Reason
    Mix-up of parts - product labeled cortical bone screw actually contains acutract fixation screw.
  • Action
    On May 18, 2009, the firm, ACUMED, began calling customers. On May 19, 2009, the ACUMED sent e-mails and a "URGENT NOTICE: DEVICE RECALL" Initial Notice letter to all customers. The letter describes the product, problem and actions to be taken by customers. The customers were instructed to identify the product having the lot code(s) and quarantine them, return all products from the lot code(s) to Acumed immediately, to please notify the customers of this recall if you further distributed this product, and complete and return the Acumed Product Recall Effectiveness Form. Please contact Acumed Customer Service at 1-888-627-9957 for any questions regarding this notification.

Device

  • Model / Serial
    Lot code 203214
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Worldwide distribution: USA including FL, GA, MI, MN, NY, TX, VA and countries of United Kingdom, Herzeles, South Korea, South Africa, China, and Milan
  • Product Description
    Polarus(R) Humeral Fixation System, size: 3.5mm x 25.0mm Cortical Screw, QTY 1, Ref: HCO3250-S Acumed, LLC Hillsboro, OR || Intended use: Acumed intramedullary rods and screws are designed to provide fixation of humeral, forearm and fibula fractures while they heal.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Acumed LLC, 5885 NW Cornelius Pass Rd, Hillsboro OR 97124-9432
  • Manufacturer Parent Company (2017)
  • Source
    USFDA