Recall of Device Recall Cook Medical

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Cook Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    73056
  • Event Risk Class
    Class 1
  • Event Number
    Z-0800-2016
  • Event Initiated Date
    2016-01-06
  • Event Date Posted
    2016-02-24
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-08-23
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Catheter, percutaneous - Product Code DQY
  • Reason
    A manufacturing process may lead to catheter tip fracture and or separation. potential adverse events may include loss of device function, medical intervention to retrieve a separated segment, or complications resulting from a separated tip occluding blood flow to end organs. these catheters are used in venous or arterial pressure monitoring, blood sampling, and administration of drugs and fluids.
  • Action
    On 1/6/2016, URGENT: MEDICAL DEVICE RECALL notifications were sent to the affected distributors and hospital Risk Management/Recall Administration via courier with instructions for identifying and returning the affected product. The recall notification included a description of the reason for the recall, affected product, consignee responsibilities, and instructions for responding to the formal recall notification. Should you have any questions or concerns, please do not hesitate to contact Cook Medical Customer Relations at (800) 457-4500 or 1(812) 339-2235.

Device

  • Model / Serial
    RPN/Catalog number: C-PMS-250 C-PMS-2502-15-3.5 C-PMS-2502-15-5.0 C-PMS-250-MONTES-A-092084 C-PMS-251 C-PMS-251J C-PMS-300 C-PMS-300-CHILDRENS-A-032988 C-PMS-300J C-PMS-301 C-PMS-301J C-PMS-301J-PKG C-PMS-400J  Lots: 6028502 6034979 6083984 6194848 NS6014456 NS6014457 6148788 6254047 5906417 6160213 NS6064797 NS6014483 NS6175149 NS6184593 NS6187516 NS6014458 5889463 5898283 5922849 5941909 5964565 5976506 6021072 6028497 6143834 6160238 NS5933957 5828147 5941919 NS5932835 NS5932836 NS6050233 NS6072523 NS6108227 NS6130497 5803601 6034985 6075213 NS5833882 NS5892109 NS5892110 NS5919920 NS6021136 NS6054843 NS6072524 NS6075557 NS6082375 NS6108228 NS6148658 6067668
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US Nationwide including DC and PR including the countries of Australia, Germany, China, Chile, Dominican Republic, Panama, Israel, Brazil, Canada
  • Product Description
    Single Lumen Pressure Monitoring Sets and Trays || The subject sets and trays are comprised of a single-lumen uncoated or heparin-coated catheter. Product catalog numbers with heparin coating are designated by the suffix BH.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Cook Inc., 750 N Daniels Way, Bloomington IN 47404-9120
  • Manufacturer Parent Company (2017)
  • Source
    USFDA