Recall of Device Recall cobas b 2212Roche OMNI S2 system

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Roche Diagnostics Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    79676
  • Event Risk Class
    Class 2
  • Event Number
    Z-1610-2018
  • Event Initiated Date
    2018-02-22
  • Event Date Posted
    2018-05-03
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Electrode, ion specific, potassium - Product Code CEM
  • Reason
    The software responsible for starting scheduled autoqc measurements (scheduler) will not activate.
  • Action
    ROCHE sent an Urgent Medical Device Correction Letter dated February 22, 2018, via UPS to affected customers. Customers were instructed to complete the following: " 1) Use the Return to Setup and Exit buttons to ensure execution of scheduled AutoQC measurements as described in this Urgent Medical Device Correction (UMDC); 2) Check to see if the next scheduled AutoQC measurement is performed to ensure the AutoQC scheduler is working as expected; 3) If your facility has distributed the affected product to another site, please ensure this UMDC is provided to that site; 4) Complete the attached fax form (TP-00146) and fax it to 1-844-491-7776 or scan and email to roche7570@stericycle.com; 5) File this UMDC for future reference. Customers with questions should contact the Roche Support Network Customer Support Center, 24 hours a day, seven days a week at 1-800-526-2272.

Device

  • Model / Serial
    3337111001 and 3337111692  UDI: 04015630018307
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    USA ( nationwide)
  • Product Description
    cobas b 221<2>Roche OMNI S2 system catalog numbers: 3337111001 and 3337111692 || The Roche Diagnostics Omni S Analyzer is a fully automated critical care analyzer intended to be used for the measurement of pH, PCO2, PO2, sodium, potassium, ionized calcium, chloride, hematocrit, glucose, lactate, urea/BUN, total hemoglobin, oxygen saturation, oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin, and methemoglobin in samples of whole blood, serum, plasma, and aqueous solutions as appropriate.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Roche Diagnostics Corporation, 9115 Hague Rd, Indianapolis IN 46256-1025
  • Manufacturer Parent Company (2017)
  • Source
    USFDA