Recall of Device Recall Cardiac Marker Control Level 1, Cardiac Marker Control Level 2, & Cardiac Marker Control Level 3

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Abbott Point Of Care Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    57742
  • Event Risk Class
    Class 2
  • Event Number
    Z-1863-2011
  • Event Initiated Date
    2010-12-17
  • Event Date Posted
    2011-04-01
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-10-16
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Single (Specified) Analyte Controls (Assayed and Unassayed) - Product Code JJX
  • Reason
    Presence of co2 in the head space of the vial can result in the generation of high results in cardiac marker control level 1, 2, and 3 which is used along with the cardiac marker control calibration verification set.
  • Action
    Urgent Recall Notice letters with business reply cards were sent Fed ex on December 17, 2010 to all accounts. International notifications were sent on December 21, 2010. The letter identified the affected product and lot numbers along with a background explanation of the issue. The firm recommends that customers remove the cap from the vial; squeeze the vial 10 times, prior to thawing; replace cap on the vial; and then follow the remaining steps for use as outlines in section 14-12 of the i-STAT 1 System Manual. Customers are to complete and return the Business Reply card to acknowledge receipt of the letter. If the affected product had been further distributed then a copy of the letter should be provided to those customers as well. If additional information is needed, customers should contact Abbott Point of Care Technical Support at 800-366-8020, Option 1 or their Abbott Point of Care representative.

Device

  • Model / Serial
    Cardiac Marker Control Level 1 - Lot number M102081; Cardiac Marker Control Level 2 - Lot number M102082; and  Cardiac Marker Control Level 3 - Lot number M102083.
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution
  • Product Description
    Cardiac Marker Control Level 1, List Number 136601-06F12-02; Cardiac Marker Control Level 2, List number 136602/06F13-02; and Cardiac Marker Control Level 3, List number 136603/06F14-02. || Used to verify the integrity of newly received i-STAT cTnI cartridges.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Abbott Point Of Care Inc., 400 College Rd E, Princeton NJ 08540-6607
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “We are in constant communication with regulatory agencies and competent authorities worldwide which allows us to implement global recalls or in-country communication quickly and effectively,” Abbott, which now owns St. Jude Medical told ICIJ in a statement. In addition to sending global notices to physicians worldwide, we also make sure that product advisories are available online and classification of product recalls and product advisories are determined by global regulatory bodies which can impact the timing in any given country. MD companies follow varying regulations in different countries. In come countries software is not regulated so a recall in one country related to software would not be classified as a recall or field action in another. In addition, review cycles within the regulatory process can be different in each country which can impact communication and recall timing.
  • Source
    USFDA