Recall of Device Recall Cannon Catheter" II,

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Arrow International Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    48706
  • Event Risk Class
    Class 2
  • Event Number
    Z-2262-2008
  • Event Initiated Date
    2008-06-10
  • Event Date Posted
    2008-09-17
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2009-12-03
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Catheter - Product Code MSD
  • Reason
    The tips may not have been adequately welded to the catheter body.
  • Action
    Consignees were notified by letter on/about 06/10/2008. They were instructed to: 1. Cease use and distribution and quarantine all affected product immediately. 2. Contact Arrows Customer Service Department for a Return Authorization Number, enter the number on an enclosed Recall Acknowledgement & Stock Status Form and 3. Immediately fax back the form to Arrow International. All affected product is to be returned to Arrow International. A letter containing the recall information was enclosed for physicians who have implanted catheters. Contact Arrow's Customer Service at 1-800-523-8446 for assistance.

Device

  • Model / Serial
    Lot# RL7065083, RL7064902, RL7054801, RL7024113, RL6103474, RL6093296, RL6083017, RL6082996, RL6062685, RL5101072, and RL5090957
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    U.S. Nationwide, Albania, Argentina, Australia, Belgium, Brazil, Canada , Chile, Colombia, Cyprus, Czech Republic, Dominican Republic, Ecuador, Finland, France, Germany, Greece, Guatemala, Hungary, India, Italy, Latvia, Liechtenstein, Lithuania, Mexico, Netherlands, New Zealand, Pakistan, Poland, Slovakia, South Africa, South Korea, Spain, Sweden, Taiwan, Tanzania, Turkey, UK and the Ukraine
  • Product Description
    Cannon¿ II Plus, Hemodialysis Catherization Set, Long-Term Access. Catheter Length, Cuff to Tip: 19cm, CSD-15242-SP, Intended for single use only, Sterile, Rx only, Arrow International, Inc., 2400 Bernville Road, Reading, PA 19605, USA || The product is used for long term hemodialysis vascular access.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Arrow International Inc, 2400 Bernville Rd, Reading PA 19605-9607