Recall of Device Recall AXIOM Artis Angiographic XRay System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Siemens Medical Solutions USA, Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    34881
  • Event Risk Class
    Class 2
  • Event Number
    Z-0809-06
  • Event Initiated Date
    2006-03-10
  • Event Date Posted
    2006-04-26
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2006-08-30
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    System, X-Ray, Angiographic - Product Code IZI
  • Reason
    The recalling firm became aware of a potential problem when imaging patients on their stomach on the axiom artis x-ray systems running software versions vb11k and vb22g. in some instances, the orientation labels could be incorrect.
  • Action
    The recalling firm has issued a Customer Safety Advisory to the affected customers per Update Instructions AX011/06/S and AX013/06/S, on 3/10/2006. This informs customers of the potential problem and provides a recommendation to avoid this issue.

Device

  • Model / Serial
    AXIOM Artis FC model number 5904433, AXIOM Artis BC model number 5904649, AXIOM Artis MP model number 5904466, AXIOM Artis FA model number 5904441, AXIOM Artis BA model number 5904656, AXIOM Artis TC model number 7728350, AXIOM Artis TA model number 7007755, AXIOM Artis dFC model number 7412807, AXIOM Artis dFC-MN model number 7727717, AXIOM Artis dBC model number 7728392, AXIOM Artis dTC model number 7413078, AXIOM Artis dFA model number 7555373, AXIOM Artis dBA model number 7555357, AXIOM Artis dTA model number 7008605, AXIOM Artis dMP model number 7555365. Software versions VB11K and VB22G.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide. The product was shipped to medical facilities in AL, AR, AZ, CA, CO, CT, DC, FL, GA, IA, ID, IL,IN, KS, KY, LA, MA, MI, MN, MO, MT, NC, NE, NJ, NV, NY, OH, OK, OR, PA, SC, TN, TX, VA, WI and WV.
  • Product Description
    AXIOM Artis X-ray systems running software versions VB11K and VB22G
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Siemens Medical Solutions USA, Inc, 51 Valley Stream Pkwy, Malvern PA 19355-1406
  • Manufacturer Parent Company (2017)
  • Source
    USFDA