Recall of Device Recall ATLANTIS(R) Anterior Cervical Plate System VARIABLE ANGLE SCREW MODULE

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Medtronic Sofamor Danek USA Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    63157
  • Event Risk Class
    Class 2
  • Event Number
    Z-0036-2013
  • Event Initiated Date
    2012-08-30
  • Event Date Posted
    2012-10-10
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2013-08-15
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Appliance, fixation, spinal intervertebral body - Product Code KWQ
  • Reason
    Lines on the screw gauge may not placed on the caddy properly which could result in improper measurement of screws. an incorrect gauge could measure a screw to be approximately 1 mm shorter than its actual length.
  • Action
    Medtronic conducted a conference call on August 30, 2012 and sent an "URGENT VOLUNTARY RECALL" notice dated September 3, 2012 to all affected customers. The notice identified the product, problem, and actions to be taken by the customers. A Recall Questionnaire Form was attached to the letter for customers to complete and return. Contact your Medtronic Sales representative or the firm's Global Quality Department at 800-876-3133, ext. 3197 for questions regarding this notice.

Device

  • Model / Serial
    All lots except those starting with SY
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Worldwide Distribution-USA (nationwide) and the countries of India, Netherlands, Hong Kong, S. L Korea, Singapore, Canada, Australia, Japan, and Mexico.
  • Product Description
    ATLANTIS(R) Anterior Cervical Plate System VARIABLE ANGLE SCREW MODULE, REF 176-503, QTY: 1 EA, Rx only, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132. || Orthopedic. || This instrument is a precision device which may incorporate a measuring function and has uses as described on the label. Unless labeled for || single use, this instrument may be re-used.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Medtronic Sofamor Danek USA Inc, 1800 Pyramid Place, Memphis TN 38132
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    USFDA