Recall of Device Recall Artis Q. zen floor

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Siemens Medical Solutions USA, Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    77908
  • Event Risk Class
    Class 2
  • Event Number
    Z-3091-2017
  • Event Initiated Date
    2016-02-18
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-11-17
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Interventional fluoroscopic x-ray system - Product Code OWB
  • Reason
    Due to a leak in the cooling system, fluids could potentially seep into the equipment cabinet. loss of coolant can results in a cooling system failure and subsequent system failure. this leek can occur sporadically in affected systems.
  • Action
    Siemens mailed a Customer Safety Advisory Notice (CSAN) dated February 18, 2016, to affected customers informing them that their service organization will contact them to arrange a date to perform the corrective action (replacement of affected plastic couplings to prevent fluid leaks). Customers were advised to contact Siemens service organization for an appointment to schedule the work For questions regarding this recall call 610-.448-6461.

Device

  • Model / Serial
    Artis Q.zen floor- Serial number: 105007 105018 105016 105017
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution
  • Product Description
    Artis zee/zeego and Artis Q/Q.zen system, x-ray, angiographic || AXIOM Artis zee and Q/Q.zen is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to , pediatric and obese patients. Procedures that can be performed with the AXIOM Artis-zee/zeego and Q/Q.zen family include cardiac angiography, neuro angiography, general angiography, rotational angiography, operating room angiography, multipurpose angiography and whole body radiographic/fluoroscopic procedures. AXIOM Artis zee/zeego and Q/Q.zen can also support the acquisition of position triggered imaging for spatial data synthesis
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Siemens Medical Solutions USA, Inc, 40 Liberty Blvd, Malvern PA 19355-1418
  • Manufacturer Parent Company (2017)
  • Source
    USFDA