Recall of Device Recall Applied Medical Kii Optical Access System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Applied Medical Resources Corp.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    59560
  • Event Risk Class
    Class 2
  • Event Number
    Z-3068-2011
  • Event Initiated Date
    2009-12-18
  • Event Date Posted
    2011-08-24
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2011-09-06
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Laparoscope, general & plastic surgery - Product Code GCJ
  • Reason
    The recall was expanded on december 22, 2009 to include four models: c0r36, c0r37, c0r38, and c0r39. initially, applied medical conducted a voluntary recall on june 9, 2009 of two lot numbers, 1084426 and 1085506, of the 15 mm kii non-threaded optical access system, model c0r36, due to a potential weakness in the cannula tip, possibly resulting in a tip breakage.
  • Action
    Applied Medical Resources Corp. notified customers via an overnight "URGENT: MEDICAL DEVICE RECALL" letter dated December 22, 2009. The letter informed customers of the recalled products, problem, and actions to be taken. The letter asked that the listed recalled products be returned immediately. The customers were asked to check their inventory, complete the attached Voluntary Recall Notification Confirmation Form and fax as per the instructions. The recall letter provided customers with a contact and telephone number for product return questions (1-949-713-8652) and a separate contact for regulatory questions (1-949-713-8369).

Device

  • Model / Serial
    1084813, 1084814, 1084820, 1089654, 1091175, 1090426
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - Nationwide in the USA and to countries of: Australia, Austria, Belgium, Canada, Chile, Columbia, Cyprus, Denmark, Finland, France, Germany, Great Britain, Hong Kong, India, Ireland, Italy, Malaysia, Netherlands, New Zealand, Norway, Poland, Portugal, Saudi Arabia, Singapore, South Africa, and Switzerland.
  • Product Description
    Applied Medical 15x100 mm Kii Optical Access Systems, Non-Threaded 6/Box, Model C0R38 || Product Usage: Applied Medical's C0R36, C0R37, C0R38, and C0R39 trocars are diposable single-use devices indicated for use in general, abdominal, gynecological and thoraic minimally invasive surgeries. Trocars establish a path of entry through tissue planes and into internal spaces for purposes of inserting endoscopic instruments that are used to perform surgery on internal organs.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Applied Medical Resources Corp, 22872 Avenida Empresa # 3, Rancho Santa Margarita CA 92688-2650
  • Manufacturer Parent Company (2017)
  • Source
    USFDA