Recall of Device Recall AMSCO C and AMSCO 400 Steam Sterilizers

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Steris Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    64440
  • Event Risk Class
    Class 2
  • Event Number
    Z-0915-2013
  • Event Initiated Date
    2013-02-12
  • Event Date Posted
    2013-03-06
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2013-12-05
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Sterilizer, steam - Product Code FLE
  • Reason
    The control boards alarm set points and temperature tolerances allowed for erroneous activation of the ad (analog/digital) alarm as temperature fluctuated during operation. when this alarm occurs, the sterilizer locks up and cannot be used until serviced, causing customer nuisance.
  • Action
    Steris Corporation initiated their recall on February 12, 2013. They will notify customers via onsite visits by STERIS Field Service Technicians to each affected Customer site. For further questions, please call (440) 392-7601.

Device

  • Model / Serial
    AMSCO C: Serial Numbers: 021911201  023461202 AMSCO 400: Serial Numbers: 030181215-030291310
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - USA including Canada and the states of AK, AL, AR, AZ, CA, CO, CT, DC, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, MS, NC, ND, NE, NH, NJ, NM, NY, OH, OK, OR, PA, SC, SD, SK, TN, TX, UT, VA, VT, WA, WI, and WV.
  • Product Description
    AMSCO C and AMSCO 400 Steam Sterilizers designed for sterilization of heat and moisture-stable materials used in healthcare facilities.