Recall of Device Recall Altaire Shoulder Coil

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Hitachi Medical Systems America Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    44702
  • Event Risk Class
    Class 2
  • Event Number
    Z-1263-2007
  • Event Initiated Date
    2007-07-30
  • Event Date Posted
    2007-09-26
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2010-10-05
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Shoulder Coil - Product Code LNH
  • Reason
    Overheating; a portion (balun assembly) of the cable that connects the shoulder coil to the actual mri unit may malfunction and result in overheating of the balun assembly. the overheating of the balun assembly could result in injury to the patient or operator if either came into contact with the assembly.
  • Action
    On 7/30/07, Hitachi sent a Device Correction letter via courier with receipt tracking to all affected customers outlining the risk of overheating of the cable balun assembly and subsequent risk of patient/operator injury. The letter notifies customers that (1) Hitachi will be contacting them in the future to schedule an on-site visit for replacement of the Altaire Shoulder Coil; (2) the replacement will begin in September, 2007 and continue until all affected coils are replaced; and (3) customers that have noticed overheating of the cable balun assembly are urged to notify Hitachi for immediate replacement service.

Device

  • Model / Serial
    Serial Numbers: 203, 303, 305, 307, 308, 309, 310, 311, 312, 313, 314, 315, 316, 317, 318, 319, 320, 321, 323, 325, 326, 327, 328, 329, 330, 332, 333, 335, 336, 337, 338, 339, 340, 341, 342, 343, 344, 345, 346, 347, 348, 349, 350, 351, 352, 353, 354, 355, 356, 357, 359, 360, 361, 362, 363, 364, 365, 366, 367, 368, 369, 370, 371, 372, 373, 374, 375, 377, 378, 379, 380, 381, 382, 383, 384, 385, 386, 387, 388, 389, 390,, 391, 392, 393, 394, 395, 396, 397, 398, 399, 400, 401, 402,, 403, 404, 405, 406, 407, 408, 410, 411, 412, 413, 414, 415 416, 417, 418, 419, 420, 421, 422, 424, 425, 426, 427, 429, 430, 431, 432, 434, 435, 436, 437, 438, 439, 440, 441, 442, 443, 445, 446, 447, 449, 450, 451, 452, 453, 454, 456, 457, 458, 460, 461, 462, 463, 464, 465, 466, 467, 468, 469, 470, 472, 473, 474, 475, 476, 477, 478, 479, 480, 481, 482, 483, 485, 486, 487, 488, 489, 491, 492, 493, 494, 495, 496, 497 499, 501, 502, 503, 504, 505, 509, 510, 512, 513, 514, 515 516, 517, 518, 519, 520, 521, 522, 523, 524, 527, 528, 529 530, 531, 532, 533, 534, 535, 536, 537, 538, 539, 540, 541, 542, 543, 544, 545, 546, 547, 548, 549, 550, 551, 552, 553, 554, 555, 556, 557, 559, 560, 561, 562, 563, 564, 565, 566, 567, 568, 570, 571, 572, 573, 574, 575, 576, 577, 578, 579, 580, 581, 582, 583, 584, 585, 586, 587, 588, 589, 590, 591, 592, 593, 594, 595, 596, 597, 598, 599, 600, 601, 602, 603.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide: U.S. A. to include: AL, AR, AZ, CA, CO, CT, DE, FL, HI, ID, IL, IN, KS, KY, LA, MD, MI, MN, MO, MS, MT, NC, NE, NJ, NM, NV, NY, OH, OK, OR, PA, SC, TN, TX, UT, VA, WA, WI, & WY.
  • Product Description
    Altaire Shoulder Coil, an accessory to the Altaire MRI system. The shoulder coil is a two-channel, receive only coil that functions at 29.641 MHz band. It consists of a cable and a coil (imaging) body. A portion of the cable is referred to as the balun assembly or balun trap. The shoulder coil assembly is packaged in a cardboard box with foam inserts.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Hitachi Medical Systems America Inc, 1959 Summit Commerce Park, Twinsburg OH 44087-2371
  • Manufacturer Parent Company (2017)
  • Source
    USFDA