Recall of Device Recall Accura System for Blood Filtration

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Baxter Healthcare Renal Div.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    32631
  • Event Risk Class
    Class 2
  • Event Number
    Z-1380-05
  • Event Initiated Date
    2005-07-13
  • Event Date Posted
    2005-08-18
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2008-10-29
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Dialyzer, High Permeability With Or Without Sealed Dialysate System - Product Code KDI
  • Reason
    In the event therapy is terminated, as part of routine instrument programming or therapy maintenance, the accura instrument may experience difficulty in performing a successful self-test (failure) upon an immediate attempt to restart therapy.
  • Action
    Baxter sent Important Product Information letters dated 7/13/05 to all Accura device customers, to the attention of the Director of Nursing, via first class mail. The letter informed the accounts of the on-going investigation into the potential self-test failure associated with the Accura instrument, and provided the customers with steps to follow if they encounter failed instrument self-tests. These guidance steps include: 1) Place the instrument into 'stand-by' mode. Generally, 15 minutes in 'stand-by' mode is sufficient to allow successful instrument self-test procedures. Enter 'stand-by' mode by turning off the power by using the upper power switch, or by selecting 'Accura off' from the user interface. Avoid selecting 'Next treatment' as this immediately puts the Accura into self-test mode. 2) After 15 minute, turn the power on. 3) After successful completion of self-test, resume therapy per the Accura Operator's Manual. 4) If the instrument still does not complete a successful self-test, additional time in 'stand-by' mode may be required. Repeat steps 1-3. 5) If repeated attempts do not yield a successful calibration test, then remove the instrument from service and contact Baxter Global Technical Services. Any questions were referred to the Center for One Baxter at 1-800-422-9837.

Device

  • Model / Serial
    All serial numbers
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide, and internationally to China and Belgium
  • Product Description
    Accura System for Blood Filtration, product codes 5M5660 and ACCURA01 (international); a hemofiltration system; Baxter Healthcare Corporation, Renal Division, McGaw Park, IL 60085, manufactured in Germany
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Baxter Healthcare Renal Div, 1620 Waukegan Rd Bldg R, Mc Gaw Park IL 60085-6730
  • Source
    USFDA