Recall of CyberKnife Robotic Radiosurgery System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Accuray Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    50208
  • Event Risk Class
    Class 2
  • Event Number
    Z-0856-2009
  • Event Initiated Date
    2008-10-30
  • Event Date Posted
    2009-01-14
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2009-09-10
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Radiation Therapy Device - Product Code JAI
  • Reason
    Product may not be tensioned properly, potentially causing unexpected rotation or descent.
  • Action
    All affected sites were notified of the potential problem via Customer Advisory Notice dated 30 October 2008. The letter states required actions that the customer should follow at the beginning of each treatment day. The tension of the belt drive and the support bolts in question will be inspected by Accuray Field Service personnel at the affected facilities. In addition, the preventive maintenance procedure will be updated to include regular inspection and replacement of the belt-drive. Any questions or concerns regarding this issue should be directed to Accuray Customer Support at 1-877-668-8667 or 1-408-716-4700 or customersupport@accuray.com.

Device

  • Model / Serial
    Model number 025007, system numbers C0158, C0078, C0141, C0160, C0128, C0178, C0179, C0152, C0110, C0113, C0130, C0060, and C0125.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution --- including USA and countries of France and Turkey.
  • Product Description
    RoboCouch Patient Support System, a component of the CyberKnife Robotic Radiosurgery System. Model number 025007, manufactured by Accuray Inc., Sunnyvale, CA || The CyberKnife is indicated for treatment planning and imageguided stereotactic radiosurgery and precision radiotherapy of lesions, tumors and conditions anywhere in the body when radiation treatment is indicated. || The RoboCouch Patient Support System is intended for use in the support and positioning of a patient during Radiosurgery and radiotherapy procedures and other medical procedures when precise positioning is required.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Accuray Inc, 1310 Chesapeake Ter, Sunnyvale CA 94089
  • Manufacturer Parent Company (2017)
  • Source
    USFDA