Recall of Centricity Enterprise Archive 4.0

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Ge Healthcare It.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    64760
  • Event Risk Class
    Class 2
  • Event Number
    Z-0833-2015
  • Event Initiated Date
    2013-04-19
  • Event Date Posted
    2014-12-19
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2016-06-10
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Device, digital image storage, radiological - Product Code LMB
  • Reason
    Ge healthcare has become aware of a potential data loss issue associated with empty path names resulting from hl-7 updates when the cache disk is almost full.
  • Action
    General Electric sent an Urgent Medical Device Correction letter dated April 19, 2013, to all affected customers. The letter instructs customers to ensure that Enterprise Archive partitions have enough free space available, in particular the cache disk should have at least 10% free space available. This could be facilitated by setting appropriate disk limits and watermarks on the individual libraries in Enterprise Archive. In case the disks are not being purged to the configured watermarks and the cache disk is almost full, customers are requested to contact their local GE service person. A permanent product correction will be provided to all customers under FMI85209R. Customers with questions were instructed to contact their local Sales/Service Representative. Also the Remote Online Center (ROC) Customer Care can be reached at 1-800-437-1171.

Device

  • Model / Serial
    Centricity Enterprise Archive versions: 4.0.x
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution including AZ, OH, WA.
  • Product Description
    Centricity Enterprise Archive is a software product for receiving, archiving and sending of medical data. DICOM devices (e..g. modalities, workstations) Communicate with the archive using the DICOM protocol (published by ACR-NEMA). The clinical use is limited to the interaction that other systems have with the Centricity Enterprise archive. The intended users for Centricity Enterprise Archive are service personnel and system administrators and non clinical users. As of V4.0 XDS enabled systems can communicate with the archive using the XDS and XDS-1 profiles (published by IHE).
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Ge Healthcare It, 540 W Northwest Hwy, Barrington IL 60010-3051
  • Manufacturer Parent Company (2017)
  • Source
    USFDA