Recall of Carestream Vue PACS; UNLIMITED READING LIC 25K EX/YR

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Carestream Health Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    66306
  • Event Risk Class
    Class 2
  • Event Number
    Z-0226-2014
  • Event Initiated Date
    2013-09-16
  • Event Date Posted
    2013-11-13
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2015-12-21
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    System, image processing, radiological - Product Code LLZ
  • Reason
    Carestream health, inc. has issued a recall when using the carestream client workstation where under very specific conditions, some images from multi-slice studies such as ct and mr may not load into the viewer application due to a software problem.
  • Action
    Carestream sent an Urgent Medical Device Recall letter dated September 13, 2013, to all affected customers via Fed Ex on September 16, 2013, informing them that a software problem may have the potential to occur under certain conditions when using the CARESTREAM Client Workstation. When certain conditions are met, it appears that the child background process completes its tasks before the parent process and as a result the parent process considers its work done and terminates. In the event that a software problem does occur, the scan may not be fluent or the image numbers may not be sequential. A software patch is currently being deployed by Carestream Health. Customers were instructed that they would be contacted by a Carestream Service Engineer to coordinate the deployment. Customers with questions were instructed to call 1-866 737 2487 or they may call the Carestream Customer Care Center at 1-800-328-2910, 8AM through 8pm Eastern Standard Time. For questions regarding this recall call 1-800-328-2910.

Device

  • Model / Serial
    Model: Vue PACS client version 11.3.2.0 / 11.3.2.4 / 11.4 Catalog Number: 1149418
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - USA including AR, AZ, CA, CO, CT, FL, IA, IL, MA, MD, ME, MN, MO, NC, NH, NV, NY, OH, OK, PA, RI, TN, UT, VA WA, and WI and Internationally to Canada, Japan, and Kuwait.
  • Product Description
    Carestream Vue PACS; UNLIMITED READING LIC < 25K EX/YR || The CARESTREAM PACS is an image management system whose intended use is to provide completely scaleable local and wide area PACS solutions for hospital and related institutions/sites, which will archive, distribute, retrieve and display images and data from all hospital modalities and information systems.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Carestream Health Inc., 150 Verona St, Rochester NY 14608-1733
  • Manufacturer Parent Company (2017)
  • Source
    USFDA