Recall of Bone Screw

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by EBI, L.P..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    51730
  • Event Risk Class
    Class 3
  • Event Number
    Z-2294-2009
  • Event Initiated Date
    2009-04-02
  • Event Date Posted
    2009-09-22
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2009-09-23
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Bone fixation appliances - Product Code HSB
  • Reason
    Some devices could have been made with raw material lots that may have inclusions, and could result in decreased strength of the device.
  • Action
    The firm sent Urgent Recall Notices to all direct accounts, hospital Risk Management and Physicians by first class mail. Letters are dated March 29, 2009, April 2, 2009 and April 16, 2009 respectively. The letter describes the problem and that that there is a possible risk of a device failure. An additional e-mail was sent on May 22, 2009 to 5 customers due to an expansion of the recall to include 4 additional items. On June 19, 2009, the firm again expanded the recall to include 2 additional products and notified customers. Questions should be directed to William Hennig, at 1.973.299.9300. ext. 1557.

Device

  • Model / Serial
    Item number 27828, lot number 697560
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Worldwide - US -NY, NJ, MI, MD, FL, GA, PR, MN, SD, OK, TX,, LA, CA, PA, OH, NV, HI, ME, NC, KS, UT, CO, TN, WV, VA, and WA. Foreign: Brazil, Colombia, Denmark, Germany, Finland, Greece, Italy, Japan, The Netherlands, Switzerland, Sweden, Portugal, Spain, United Kingdom, Saudi Arabia, and Trinidad.
  • Product Description
    Bone Screw 4.5MM X 28MM Bone Screw Lock, Rx only || Biomet, 100 Interpace Parkway, Parsippany, NJ 070454 || The screw devices are an internal fixation device intended to aid in the alignment and stabilization of fractures to the skeletal system until healing has occurred. Implants used in this application include non sterile and sterile bone screws.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    EBI, L.P., 100 Interpace Pkwy, Parsippany NJ 07054-1149
  • Source
    USFDA