Recall of ARTISTE or ONCOR Linear Accelerators in combination with 160MLC

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Siemens Medical Solutions USA, Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    61580
  • Event Risk Class
    Class 2
  • Event Number
    Z-1493-2012
  • Event Initiated Date
    2012-04-03
  • Event Date Posted
    2012-05-07
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-07-25
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Accelerator, linear, medical - Product Code IYE
  • Reason
    Siemens became aware of a potential safety risk related to the behavior of the 160 mlc when using the "motion stop" button followed by "reset" several times during the treatment of one beam or one segment (issue 1). additionally, there may be a potential for collision if the operator does not ensure clearance of the extended flat panel positioner for all gantry rotation angles (issue 2).
  • Action
    Siemens sent a Safety Advisory Notice with Update to all affected customers. The notice informed the customers of the risk of pressing the Motion Stop button repeatedly during treatment. Work Steps were provided for customers to follow.

Device

  • Model / Serial
    Product Model with Part Number: ARTISTE MV System, 8139789; ONCOR Avant Garde, 5863472; ONCOR Impression, 5857920; ONCOR Impression, Plus 5857912; ONCOR Expression, 7360204; ONCOR Expression, 7360717
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - USA including the states of CA, DE, FL, IL, KY, LA, MA, MI, NE, NJ, NY, OH, PA, SD, TN, UT, WI, and WV
  • Product Description
    ARTISTE or ONCOR Linear Accelerators in combination with 160MLC (Multi Leaf Collimator). Linear Accelerators that may be affected are: ARTISTE MV System; ONCOR Avant Garde ONCOR Impression ONCOR Impression Plus ONCOR Expression. Manufactured by Siemens AG, Medical Solutions, Kemnath, Germany; Registered by Siemens Medical Solutions, Concord, CA. ARTISTE and ONCOR family of Linear Accelerators are used to deliver X-ray photon and electron radiation for the therapeutic treatment of cancer. || Product Model with Part Number: || ARTISTE MV System, 8139789; || ONCOR Avant Garde, 5863472; || ONCOR Impression, 5857920; || ONCOR Impression, Plus 5857912; || ONCOR Expression, 7360204; || ONCOR Expression, 7360717. || ARTISTE and ONCOR family of Linear Accelerators are used to deliver X-ray photon and electron radiation for the therapeutic treatment of cancer.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Siemens Medical Solutions USA, Inc, 4040 Nelson Ave, Concord CA 94520-1200
  • Source
    USFDA