Recall of Alteon HA Femoral Stems

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Exactech, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    78936
  • Event Risk Class
    Class 2
  • Event Number
    Z-0538-2018
  • Event Initiated Date
    2017-10-09
  • Event Date Posted
    2018-01-18
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate - Product Code MEH
  • Reason
    Wrong device description of the label identifying the implant.
  • Action
    Exactech sent an Urgent Medical Device Recall letter dated October 9, 2017, informing them of the potential mislabel. The notice requested consignees: Immediately cease distribution/use of this product; Extend information to accounts in possession of the product; Identify and quarantine any subject devices in their inventory; Complete and return Recall Acknowledgement and Recall Inventory Response Forms. For further questions, please call (800) 392-2832.

Device

  • Model / Serial
    Catalog #: 190-30-05 Serial#'s: 4897288, 4897291, 4897293, 4907465, 4907466, 4907467, 4907469, 4907472, 4907475, 4907476, 4907477, 4907478, 4907479, 4907481, 4943094, 4943095, 4943096, 4943097, 4943102, 4943104,  4943105, 4943106, 4984977, 4984978, 4984979, 4984980, 4984981,  4984982, 5046901, 5046902, 5046903, 5046904, 5046905, and 5046906.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    US Distribution to the states of : AL, CA, CO, FL, MD. and NY
  • Product Description
    Alteon HA Femoral Stem, Press-Fit, Extended Offset, Cementless, HA Coated, Collared, Size 5 || All Exactech Hip Systems are indicated for use in skeletally mature individuals undergoing primary surgery for hip replacement due to osteoarthritis, rheumatoid arthritis, osteonecrosis, post-traumatic degenerative problems of the hip, and for treatment of proximal femoral fractures where prosthetic replacement is determined by the surgeon as the preferred treatment. Components of Exactech Hip Systems are also potentially indicated for ankylosing spondylitis, congenital hip dysplasia, revision of failed previous reconstructions where sufficient bone stock is present, and to restore mobility resulting from previous fusion. Exactech Alteon HA femoral stems are intended for press-fit fixation.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Exactech, Inc., 2320 NW 66th Ct, Gainesville FL 32653-1630
  • Manufacturer Parent Company (2017)
  • Source
    USFDA