According to Saudi Food & Drug Authority, this translation missing: en.activerecord.attributes.event.types.recall_field_safety_notice involved a device in Saudi Arabia that was produced by GE Healthcare.

What is this?

Field safety notices are communications sent out by medical device manufacturers or their representatives in relation to actions that they may be taking in relation to their product that is on the market. These are mainly for health workers, but also for users. They can include recalls and alerts.

Learn more about the data here
  • Type of Event
    Recall / Field Safety Notice
  • Event ID
    mdprc 159 04 18 000
  • Event Initiated Date
    2018-04-30
  • Event Country
  • Event Source
    SFDA
  • Event Source URL
  • Notes / Alerts
    Saudi data is current through January 2019. All of the data comes from the Saudi Food & Drug Authority, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Saudi Arabia.
  • Extra notes in the data
    Report Source: NCMDR
    SFDA urges all hospitals that have devices subjected to recall, to contact the company.
  • Reason
    When the gantry front cover is removed to allow servicing of components inside the gantry, cover dollies are used to manipulate the cover. during the removal or reattachment of the front cover, a bracket can contact an internal power supply cable and damage that cable’s insulation. this can expose the conductor of a 120vac power supply cable and electrify the cover dolly, thereby introducing the risk of an electrical shock hazard to the service personnel.

Device

  • Model / Serial
    The following CT systems are affected: Revolution EVO (Models 5454001-61 GTIN 00840682109796, 5454001-160 GTIN 00840682109796, 5454001-60 GTIN 00840682109796, 5454001-260 GTIN 00840682109796) Optima CT660 (Models 5454001, 5454001-41, -100, -220, -200, -40, -22, -140, -240, -122, -222) Optima CT670/680 (Model 5454001-230, 5454001-330) Optima CT540 (Models 5432539 GTIN 00840682138963, 5432539-2 GTIN 00840682138963, 5432539-3 GTIN 00840682102551, 5432539-5 GTIN 00840682102551, 6447929)
  • Product Description
    X-ray system, diagnostic, computed tomography
  • Manufacturer

Manufacturer