translation missing: en.activerecord.attributes.event.titles.recall_field_safety_notice

According to Saudi Food & Drug Authority, this translation missing: en.activerecord.attributes.event.types.recall_field_safety_notice involved a device in Saudi Arabia that was produced by Medacta International SA.

What is this?

Field safety notices are communications sent out by medical device manufacturers or their representatives in relation to actions that they may be taking in relation to their product that is on the market. These are mainly for health workers, but also for users. They can include recalls and alerts.

Learn more about the data here
  • Type of Event
    Recall / Field Safety Notice
  • Event ID
    mdprc 055 03 13 000
  • Event Initiated Date
    2013-03-10
  • Event Country
  • Event Source
    SFDA
  • Event Source URL
  • Notes / Alerts
    Saudi data is current through January 2019. All of the data comes from the Saudi Food & Drug Authority, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Saudi Arabia.
  • Extra notes in the data
    Report Source: NCAR
    SFDA urges all hospitals that have devices subjected to recall, to contact the company.
  • Reason
    After a fracture of a stem neck due to scratches made by the surgeon during a femoral head revision, medacta has decided to modify the ifu of its hip implants adding the following sentence, valid for all the stems manufactured by medacta: "the operating surgeon has to be aware that a scratched neck can have an influence to the endurance of the stem and can lead to an early fracture of the stem neck".

Device

  • Model / Serial
    code 75.09.017 rev.13 and previous
  • Product Description
    Hip prosthesis, internal, femoral component
  • Manufacturer

Manufacturer