Safety Alert for MiniMed Sure-T infusion sets

According to Department of Health, this safety alert involved a device in Hong Kong that was produced by Medtronic.

What is this?

Alerts provide important information and recommendations about products. Even though an alert has been issued, it does not necessarily mean a product is considered to be unsafe. Safety Alerts, addressed to health workers and users, may include recalls. They can be written by manufacturers, but also by health officials.

Learn more about the data here
  • Type of Event
    Safety alert
  • Date
    2015-06-11
  • Event Date Posted
    2015-06-11
  • Event Country
  • Event Source
    DH
  • Event Source URL
  • Notes / Alerts
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Extra notes in the data
    Medical Device Safety Alert
  • Reason
    Medical device safety alert: medtronic minimed sure-t infusion sets medical device manufacturer, medtronic, has issued a medical device safety alert concerning its minimed sure-t infusion sets. the manufacturer has identified that certain minimed sure-t infusion sets had a slight increase in reports where the steel needle broke during use. in a small number of these reported cases, the needle break led to hospitalization for the management of glucose levels and/or treatment for removal of the needle. since then, an improvement in the needle manufacturing was implemented, which has reduced the number of reported cases of needle breaks. according to the manufacturer, if a needle break occurs, insulin delivery is interrupted and the pump will not alarm to notify users. the interruption of insulin delivery can cause hyperglycemia, which, if left untreated, can result in diabetic ketoacidosis. the manufacturer advises users to consult their healthcare professional if they experience a needle break while the infusion set is inserted. the manufacturer will replace the affected products if needed and advises users to follow the instructions for use carefully if they continue using the affected products. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 11 june 2015.

Device

  • Model / Serial
  • Product Description
    Medical Device Safety Alert: Medtronic MiniMed Sure-T infusion sets
  • Manufacturer

Manufacturer

  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    DH