Safety Alert for LUCAS 2 Chest Compression System

According to Department of Health, this safety alert involved a device in Hong Kong that was produced by Jolife AB.

What is this?

Alerts provide important information and recommendations about products. Even though an alert has been issued, it does not necessarily mean a product is considered to be unsafe. Safety Alerts, addressed to health workers and users, may include recalls. They can be written by manufacturers, but also by health officials.

Learn more about the data here
  • Type of Event
    Safety alert
  • Date
    2018-02-23
  • Event Date Posted
    2018-02-23
  • Event Country
  • Event Source
    DH
  • Event Source URL
  • Notes / Alerts
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Extra notes in the data
    Medical Device Safety Alert
  • Reason
    Medical device safety alert: jolife ab lucas 2 chest compression system the therapeutic goods administration (tga) of australia has issued a medical device safety alert concerning lucas 2 chest compression system [item number: 3302430-145; multiple affected serial numbers; manufactured between september 2014 and april 2015], manufactured by jolife ab. the manufacturer has become aware of a potential reliability issue where the lucas device may not respond to the push of certain buttons due to potential damage of an internal cable. the user control panel cable can be damaged by rubbing against an adjacent cable connector. if the malfunction were to occur, it may cause the device to exhibit one of the following: the device does not change from one active mode to the other the device does not begin compressions the device does not temporarily stop and lock in the start position when the pause button is pressed the manufacturer will arrange for replacement of an internal cable. users are advised to refer to sections 3.8 and 5.4 of the instruction for use, which states that if there are interruptions, if the compressions are not sufficient, or something unusual occurs during operation: push on/off for 1 second to stop lucas and remove the device from the patient. immediately start manual chest compressions. for details, please refer to the tga’s website: http://apps.Tga.Gov.Au/prod/sara/arn-detail.Aspx?k=rc-2018-rn-00147-1 posted on 23 february 2018.

Device

  • Model / Serial
  • Product Description
    Medical Device Safety Alert: Jolife AB LUCAS 2 Chest Compression System
  • Manufacturer

Manufacturer

  • Manufacturer Parent Company (2017)
  • Source