Safety Alert for HeartStart MRx monitor/defibrillator

According to Department of Health, this safety alert involved a device in Hong Kong that was produced by Philips Healthcare.

What is this?

Alerts provide important information and recommendations about products. Even though an alert has been issued, it does not necessarily mean a product is considered to be unsafe. Safety Alerts, addressed to health workers and users, may include recalls. They can be written by manufacturers, but also by health officials.

Learn more about the data here
  • Type of Event
    Safety alert
  • Date
    2012-03-21
  • Event Country
  • Event Source
    DH
  • Event Source URL
  • Notes / Alerts
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Extra notes in the data
    Medical Device Safety Alert
  • Reason
    Field safety notice: philips heartstart mrx monitor/defibrillator medical device manufacturer, philips healthcare, has issued a customer information letter concerning heartstart mrx monitor/defibrillator, models m3535a, m3536a, m3536m, m3536mc, m3536m2, m3536m4,m3536m5, m3536m6. according to philips, the heartstart mrx instructions for use (ifu) have been improved to better clarify c02/etc02 measurements taken by the mrx devices with software versions f.02, r.02, 9.Xx or earlier versions. an addendum to the ifu has been issued. according to the local supplier, the affected devices were distributed to hong kong. the customer information letter and the ifu addendum will be sent to all affected customers. if you are in possession of the products, please contact your supplier for necessary actions.

Device

  • Model / Serial
  • Product Description
    Medical Device Safety Alert: Philips HeartStart MRx monitor/defibrillator
  • Manufacturer

Manufacturer

  • Manufacturer Parent Company (2017)
  • Source
    DH