Safety Alert for Alenti Lift and Hygiene Chair

According to Department of Health, this safety alert involved a device in Hong Kong that was produced by ArjoHuntleigh.

What is this?

Alerts provide important information and recommendations about products. Even though an alert has been issued, it does not necessarily mean a product is considered to be unsafe. Safety Alerts, addressed to health workers and users, may include recalls. They can be written by manufacturers, but also by health officials.

Learn more about the data here
  • Type of Event
    Safety alert
  • Date
    2013-05-08
  • Event Date Posted
    2013-05-08
  • Event Country
  • Event Source
    DH
  • Event Source URL
  • Notes / Alerts
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Extra notes in the data
    Medical Device Safety Alert
  • Reason
    Medical device safety alert: arjohuntleigh alenti lift and hygiene chair health canada has issued a medical device safety alert, concerning alenti lift and hygiene chair., manufactured by arjohuntleigh. arjohuntleigh, in collaboration with health canada, issued the safety notice to re-iterate safety information to prevent the risk of chair tipping and patient falls with the alenti lift and hygiene chair. these incidents can be caused by operator use error and patient factors, and can lead to serious patient injury or death. between 2004 and 2007, arjohuntleigh conducted field safety correction actions to provide improved safety instructions and warnings to reduce the risk of alenti chair tipping and patient falls. the incident rate has since declined; however, arjohuntleigh continues to receive several incident reports in canada each year. to further reduce the number of incidents associated with the alenti chair, arjohuntleigh would like to re-iterate the following important safety information. alenti chair tipping and patient falls can occur if an operator fails to strictly follow all operating and safety instructions in the instructions for use. alenti chair tipping and patient falls have continued to occur in canada, some of them leading to serious patient injuries and death. all personnel who may be involved in operating the alenti chair should be familiar with the risk factors that are known to cause chair tipping and patient falling incidents. for details, please visit the following health canada website: http://healthycanadians.Gc.Ca/recall-alert-rappel-avis/hc-sc/2013/ 29019a-eng.Php if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 08 may 2013.

Device

  • Model / Serial
  • Product Description
    Medical Device Safety Alert: ArjoHuntleigh Alenti Lift and Hygiene Chair
  • Manufacturer

Manufacturer