Recall of SYNTHES (USA)MODULAR BLADE PLATE SYSTEM- 100MM SPIRAL BLADE

According to Health Canada (via FOI), this recall involved a device in Canada that was produced by SYNTHES (CANADA) LTD..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    103909
  • Event Risk Class
    II
  • Event Initiated Date
    2010-10-22
  • Event Country
  • Event Source
    HC
  • Notes / Alerts
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Extra notes in the data
  • Reason
    Synthes is initiating a recall on all lots of the synthes spiral blade associated with the modular blade plate system due to a potential for an out of specification star grind teeth of the spiral plate. the potential of insufficient depth of the spiral blade star grind teeth could lead to loosening of the coupling screw. this may present a potential risk to the patient including loss of reduction construct failure and need for additional surgical intervention.

Device

  • Model / Serial
    Model Catalog: 02.122.600 (Lot serial: ALL LOTS); Model Catalog: 02.122.601 (Lot serial: ALL LOTS); Model Catalog: 02.122.571 (Lot serial: ALL LOTS); Model Catalog: 02.122.586 (Lot serial: ALL LOTS); Model Catalog: 02.122.606 (Lot serial: ALL LOTS); Model Catalog: 02.122.605 (Lot serial: ALL LOTS); Model Catalog: 02.122.585 (Lot serial: ALL LOTS); Model Catalog: 02.122.570 (Lot serial: ALL LOTS); Model Catalog: 02.122.551 (Lot serial: ALL LOTS); Model Catalog: 02.122.615 (Lot serial: ALL LOTS); Model Catalog: 02.122.580 (Lot serial: ALL LOTS); Model Catalog: 02.122.581 (Lot serial: ALL LOTS); Model Catalog: 02.122.616 (Lot serial: ALL LOTS); Model Catalog: 02.122.575 (Lot serial: ALL LOTS); Model Catalog: 02.122.576 (Lot serial: ALL LOTS); Model Catalog: 02.122.620 (Lot serial: ALL LOTS); Model Catalog: 02.122.621 (Lot serial: ALL LOTS); Model Catalog: 02.122.565 (Lot serial: ALL LOTS); Model Catalog: 02.122.561 (Lot serial: ALL LOTS); Model Catalog: 02.122.560 (Lot serial: ALL LOTS); Model Catalog: 02.122.5
  • Product Description
    SYNTHES MODULAR BLADE PLATE SYSTEM 100MM SPIRAL BLADE