Recall of SYNGO.VIA

According to Health Canada (via FOI), this recall involved a device in Canada that was produced by SIEMENS HEALTHCARE LIMITED.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    98371
  • Event Risk Class
    III
  • Event Initiated Date
    2018-01-11
  • Event Country
  • Event Source
    HC
  • Notes / Alerts
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Extra notes in the data
  • Reason
    The manufacturer has identified a limitation within the syngo.Via vb20a reporting sections. after entering the findings information using the findings assistant or the interactive findings dialogue (ifd) user may check the finding information within the report. in case a correction of finding information should be needed user does the correction in "findings information" section or "summary of measured findings" section. in vb20a versions listed this feature is not working as expected: the corrected values modified in the report are neither saved nor printed nor sent to information system. the system will still use the former values. if the late modifications done on the syngo.Via evidence report are not noticed later when creating the formal report in the reporting system outdated information could be sent to the referring physician.

Device

  • Model / Serial
    Model Catalog: 10496180 (Lot serial: 101689); Model Catalog: 10496180 (Lot serial: 101928); Model Catalog: 10496180 (Lot serial: 101568); Model Catalog: 10496180 (Lot serial: 101386); Model Catalog: 10496180 (Lot serial: 109939); Model Catalog: 10496180 (Lot serial: 101075); Model Catalog: 10496180 (Lot serial: 131196); Model Catalog: 10496180 (Lot serial: 101414); Model Catalog: 10496180 (Lot serial: 101401); Model Catalog: 10496180 (Lot serial: 130766); Model Catalog: 10496180 (Lot serial: 101511); Model Catalog: 10496180 (Lot serial: 131273); Model Catalog: 10496180 (Lot serial: 130294); Model Catalog: 10496180 (Lot serial: 222377); Model Catalog: 10496180 (Lot serial: 102241); Model Catalog: 10496180 (Lot serial: 130666)
  • Product Description
    SYNGO.VIA
  • Manufacturer

Manufacturer

  • Manufacturer Address
    OAKVILLE
  • Manufacturer Parent Company (2017)
  • Source
    HC