Recall of OPTIMA XR220AMX X-RAY SYSTEM

According to Health Canada (via FOI), this recall involved a device in Canada that was produced by GENERAL ELECTRIC CANADA (OPERATING AS GE HEALTHCARE).

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    25788
  • Event Risk Class
    III
  • Event Initiated Date
    2012-07-20
  • Event Country
  • Event Source
    HC
  • Notes / Alerts
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Extra notes in the data
  • Reason
    The service procedure for wheel and caster replacement in the service documentation does not contain sufficient warnings to ensure the service representative has placed the tube into locked position to ensure it does not swing out and change the center of gravity of the unit thus resulting in the unit tipping over. it is also recommended to clear the work area of unnecessary personnel prior to performing this repair. the fall of the system may create a hazard to service personnel.

Device

  • Model / Serial
    Model Catalog: 5555000-5 (Lot serial: >10 numbers contact mfg); Model Catalog: 5555000-6 (Lot serial: >10 numbers contact mfg); Model Catalog: 5555000 (Lot serial: >10 numbers contact mfg); Model Catalog: 5555000-2 (Lot serial: >10 numbers contact mfg); Model Catalog: 5555000-4 (Lot serial: 00001027061WK9); Model Catalog: 5555000-3 (Lot serial: 00001027061WK9); Model Catalog: 5555000-4 (Lot serial: 00001028024WK6); Model Catalog: 5555000-3 (Lot serial: 00001028024WK6); Model Catalog: 5555000-4 (Lot serial: 00001027893WK5); Model Catalog: 5555000-3 (Lot serial: 00001027893WK5); Model Catalog: 5555000-3 (Lot serial: 00001027195WK5); Model Catalog: 5555000-3 (Lot serial: 00001027826WK5); Model Catalog: 5555000-4 (Lot serial: 00001027300WK1); Model Catalog: 5555000-3 (Lot serial: 00001027300WK1); Model Catalog: 5555000-4 (Lot serial: 00001027263WK1); Model Catalog: 5555000-3 (Lot serial: 00001027263WK1); Model Catalog: 5555000-4 (Lot serial: 00001027195WK5); Model Catalog: 5555000-4 (Lot serial: 00001027826WK5)
  • Product Description
    OPTIMA XR220AMX X-RAY SYSTEM