Recall of ICHEM VELOCITY AUTOMATED URINE CHEMISTRY SYSTEM W LOAD/UNLOAD

According to Health Canada (via FOI), this recall involved a device in Canada that was produced by BECKMAN COULTER CANADA L.P..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    146351
  • Event Risk Class
    II
  • Event Initiated Date
    2018-03-05
  • Event Country
  • Event Source
    HC
  • Notes / Alerts
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Extra notes in the data
  • Reason
    Beckman coulter has determined that there is a potential for incorrect settings to be installed on north american ichemvelocity urine chemistry analyzers. - the installation of international settings can result in the generation of erroneous false low results for some of the analytes at some concentrations. - the installation of colors different from those stated in the instructions for use (colorless straw yellow amber red blue) for output settings will result in incorrect reporting of colors. for example if green is the color choice for the output setting instead of blue green will be reported.

Device

  • Model / Serial
    Model Catalog: 800-7167 (Lot serial: ALL); Model Catalog: 800-7714 (Lot serial: ALL); Model Catalog: 800-7713 (Lot serial: ALL); Model Catalog: 800-3079 (Lot serial: ALL); Model Catalog: 800-7720 (Lot serial: ALL); Model Catalog: 800-3049 (Lot serial: ALL); Model Catalog: 800-7719 (Lot serial: ALL); Model Catalog: 800-7715 (Lot serial: ALL); Model Catalog: 800-3080 (Lot serial: ALL); Model Catalog: 800-3050 (Lot serial: ALL)
  • Product Description
    ICHEM VELOCITY AUTOMATED URINE CHEMISTRY SYSTEM W LOAD/UNLOAD;IRICELL 2000 PLUS;IRICELL 3000 PLUS;ICHEM VELOCITY AUTOMATED URINE CHEMISTRY SYSTEM BACK INTEGRATED;IRICELL 2000 PRO;ICHEM VELOCITY AUTOMATED URINE CHEMISTRY SYSTEM;IRICELL 1000 PLUS;IRICELL 30