Recall of DUAL HEAD GENESYS NUCLEAR MEDICINE IMAGING UNIT

According to Health Canada (via FOI), this recall involved a device in Canada that was produced by PHILIPS MEDICAL SYSTEMS CANADA A DIVISION OF PHILIPS ELECTRONICS LTD..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    30613
  • Event Risk Class
    II
  • Event Initiated Date
    2002-12-06
  • Event Country
  • Event Source
    HC
  • Notes / Alerts
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Extra notes in the data
  • Reason
    System does not provide a warning to the user if the collision detection circuitry has been disabled via a hardware jumper on an electronic board in the camera. there is a potential risk of patient injury.

Device

  • Model / Serial
    Model Catalog: (Lot serial: 219); Model Catalog: (Lot serial: 9601238); Model Catalog: (Lot serial: 9602249); Model Catalog: (Lot serial: 9512037); Model Catalog: (Lot serial: 9508171); Model Catalog: (Lot serial: 9503085); Model Catalog: (Lot serial: 9501159); Model Catalog: (Lot serial: 9507165); Model Catalog: (Lot serial: 9308009); Model Catalog: (Lot serial: 9408139); Model Catalog: (Lot serial: 9310029); Model Catalog: (Lot serial: 9308010); Model Catalog: (Lot serial: 9804227); Model Catalog: (Lot serial: UNK-01755FS); Model Catalog: (Lot serial: 911161); Model Catalog: (Lot serial: ); Model Catalog: (Lot serial: 908132); Model Catalog: (Lot serial: 108282); Model Catalog: (Lot serial: 9506018); Model Catalog: (Lot serial: 112019); Model Catalog: (Lot serial: 903134); Model Catalog: (Lot serial: 908146); Model Catalog: (Lot serial: A01100225); Model Catalog: (Lot serial: 9908167); Model Catalog: (Lot serial: A0105216); Model Catalog: (Lot serial: A0106218); Model Catalog: (L
  • Product Description
    DUAL HEAD GENESYS
  • Manufacturer

Manufacturer