Safety Alert for FLO-GARD VOLUMETRIC INFUSION PUMP. MODELS 6200, 6201, 6300 AND 6301 .. RISK CLASS III.

According to Agência Nacional de Vigilância Sanitária (ANVISA), this safety alert involved a device in Brazil that was produced by Baxter Hospitalar Ltda..

What is this?

Alerts provide important information and recommendations about products. Even though an alert has been issued, it does not necessarily mean a product is considered to be unsafe. Safety Alerts, addressed to health workers and users, may include recalls. They can be written by manufacturers, but also by health officials.

Learn more about the data here
  • Type of Event
    Safety alert
  • Event ID
    881
  • Date
    2007-08-08
  • Event Country
  • Event Source
    ANVISA
  • Event Source URL
  • Notes / Alerts
    Brazilian data is current through June 2018. All of the data comes from Anvisa, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Brazil.
  • Extra notes in the data
    Baxter Hospital Ltda informs that the risks associated with absence of alarm when occlusion occurs above the flexible chamber of the infusion pump are: the return flow of the patient's blood, the loss of the infusion line or the non-administration of the drug to the patient. Still according to Baxter, the conditions that may potentially cause these situations are as follows: (1) when the vial or pouch has been emptied, but the pump continues to pump; (2) when the spike was not completely inserted into the bottle or pouch; (3) when a rigid bottle (glass bottle, for example) or semi-rigid bottle (Buretrol, for example) is improperly vented. In these cases, according to the addendum to the manual, specific prevention measures should be observed. Anvisa's Technovigilance Unit is monitoring this case.
  • Reason
    Infusion pump alarm may not work when occlusion occurs above the flexible chamber of the equipment.
  • Action
    Baxter Hospitalar do Brasil Ltda has already located the customers involved and has forwarded to them an addendum to the equipment operation manual. This addendum informs about the possibility that the pump does not alarm when there is occlusion above the flexible chamber, defines the situations in which this problem may occur and indicates the additional precautions to be observed.