Recall of VITEK MS Clinical Systems. An in vitro diagnostic medical device (IVD)

According to Department of Health, Therapeutic Goods Administration, this recall involved a device in Australia that was produced by Biomerieux Australia Pty Ltd.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    RC-2017-RN-00909-1
  • Event Risk Class
    Class II
  • Event Initiated Date
    2017-08-03
  • Event Country
  • Event Source
    DHTGA
  • Event Source URL
  • Notes / Alerts
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Extra notes in the data
  • Reason
    The vitek ms system could give, in specific conditions, an incorrect identification result if the tested species is not included in the vitek ms knowledge base (kb). when the microorganism tested is not part of the training dataset, no specific species pattern will be available in the database for comparison. consequently, the system can give:1) no identification when the spectrum acquired does not match with any species pattern.2) a low discrimination identification when the spectrum acquired presents a high level of similarity with multiple specific species patterns present in the database.3) an incorrect single choice identification to the nearest pattern species when the spectrum acquired presents a high level of similarity with a specific species pattern present in the database.This is a system limitation with all maldi-tof databases which is currently not described in the user manual.
  • Action
    Biomerieux is requesting customers: 1. Distribute the supplied information to all appropriate personnel in your laboratory, retain a copy in your files, and forward the customer letter to all parties that may use this product, including others to whom you may have transferred our product; 2. Take this limitation into account; 3. Contact your local Customer Service in case of questions; and 4. Complete and return the supplied Acknowledgement Form in Attachment A by Fax to confirm receipt of this notice