Recall of SynchroMed II Implantable Drug Infusion Pump

According to Department of Health, Therapeutic Goods Administration, this recall involved a device in Australia that was produced by Medtronic Australasia Pty Ltd.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    RC-2016-RN-01458-1
  • Event Risk Class
    Class I
  • Event Initiated Date
    2016-11-24
  • Event Country
  • Event Source
    DHTGA
  • Event Source URL
  • Notes / Alerts
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Extra notes in the data
  • Reason
    This communication is an update to medtronic’s march 2014 notification regarding the potential for synchromed ii pump over-infusion. “over-infusion” is defined as the delivery of more drug volume than the programmed rate, exceeding the pump’s flow rate accuracy specification. pump reservoir contents that are less than expected may indicate that the pump has over-infused. over-infusion may or may not be associated with clinically relevant symptoms. when the pump delivers more drug volume than the programmed rate, patients may experience overdose symptoms. patients may experience under-dose or withdrawal symptoms if the drug is depleted prior to the scheduled refill date from an over-infusing pump. the low reservoir alarm of an over-infusing pump will not sound if the pump reservoir is prematurely depleted. the low reservoir alarm is calculated from the pump’s programmed delivery rate and is not a direct measurement of the actual drug volume remaining in the reservoir.
  • Action
    Medtronic is communicating the appropriate patient management recommendations and guidelines to the clinicians managing the patients implanted with the affected devices. For more details, please see https://www.tga.gov.au/alert/medtronic-synchromed-ii-implantable-infusion-pump . This action has been closed-out on 26/05/2017.

Device

Manufacturer

  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.