Recall of Spectra Optia Apheresis Systems

According to Department of Health, Therapeutic Goods Administration, this recall involved a device in Australia that was produced by Terumo BCT Australia Pty Ltd.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    RC-2017-RN-00626-1
  • Event Risk Class
    Class II
  • Event Initiated Date
    2017-05-16
  • Event Country
  • Event Source
    DHTGA
  • Event Source URL
  • Notes / Alerts
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Extra notes in the data
  • Reason
    During routine testing by the manufacturer, a device that is similar to the spectra optia system demonstrated a non-recoverable power failure. a subsequent investigation determined that a power filter cable, a component used in the internal electrical system, had a visible defect that caused the unit to lose power. specific serial numbers of the spectra optia systems contain these cables and therefore there is a possibility these systems could encounter a non-recoverable power failure. if a power failure occurs prior to starting the procedure, the failure could result in the delay of the procedure until the device is repaired or another device is available. if a power failure occurs after the procedure has begun, the procedure cannot be completed, and automated rinseback cannot be performed.To date, the manufacturer has not received any customer reports of a non-recoverable power failure experienced in any spectra optia system with the possibly affected cables.
  • Action
    Terumo is advising users that they will be replacing the affected cables. A Terumo sales representative will contact users to schedule a visit for the cable replacement. In the interim, the Spectra Optia system can continue to be used in accordance with the operator’s manual and the operator training materials, which include instructions for manual rinseback.

Device

  • Model / Serial
    Spectra Optia Apheresis SystemsSerial Number Range: 1P04028 to 1P04392ARTG Number: 130529