Recall of PHILIPS MX 16-slice CT System, software: v1.1.3.1167; v1.1.4.21425; v1.1.4.21424; v1.1.4.21422

According to Department of Health, Therapeutic Goods Administration, this recall involved a device in Australia that was produced by Philips Electronics Australia Ltd.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    RC-2014-RN-01105-1
  • Event Risk Class
    Class II
  • Event Initiated Date
    2014-10-10
  • Event Country
  • Event Source
    DHTGA
  • Event Source URL
  • Notes / Alerts
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Extra notes in the data
  • Reason
    The orientation of images is displayed incorrectly. when operator chooses “gantry on the right side” from operation console, and the patient position is hfdl, hfdr, ffdl or ffdr, the patient position picture and text is not consistent. "l" and "r" of scan images are reversed and this is not consistent with the patient actual position. this issue may result in potential misdiagnosis or incorrect anatomy classification leading to unnecessary treatment/procedure.
  • Action
    Philips is providing temporary work around instructions in the customer letter until updated software in a Service Pack is installed in the affected systems. The Service Pack will also correct the following other issues: - When a surview which is longer than 557mm is stopped by using “Abort” function during the scan process, the position of scan box in surview image is not correct. - For dental applications, when a patient scan is taken with Gantry tilted, and the tilt angle falls in the range from 1 to -1 degree (not including 0 degree position), the data post-processing may not operate normally and the images may not be displayed. - If the user stops a surview using the “Abort” function during the second part of the scan, the positions of the scan box are not consistent. This action has been closed-out on 09/08/2016.

Device

  • Model / Serial
    PHILIPS MX 16-slice CT System, software: v1.1.3.1167; v1.1.4.21425; v1.1.4.21424; v1.1.4.21422ARTG number: 98868