Recall of Medtronic Consulta CRT-P (Implantable cardiac pacemaker)

According to Department of Health, Therapeutic Goods Administration, this recall involved a device in Australia that was produced by Medtronic Australasia Pty Ltd.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    RC-2013-RN-00572-1
  • Event Risk Class
    Class I
  • Event Initiated Date
    2013-06-14
  • Event Country
  • Event Source
    DHTGA
  • Event Source URL
  • Notes / Alerts
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Extra notes in the data
  • Reason
    Medtronic recently identified an issue with a subset of consulta® crt-p devices during production. this issue was identified as a result of an internal investigation that indicated a recent trend of increasing manufacturing rejects related to the weld of a connector bracket. an out-of-specification weld could result in a loss of device hermeticity and compromised device functionality.
  • Action
    Medtronic is requiring the return of non-implanted devices manufactured between April 1 and May 13, 2013 for re-inspection. Currently there are currently no specific patient management recommendations for implanted Consulta CRT-P device patients. Patients should continue to be followed regularly in accordance with product labelling. This issue continues to be evaluated and any changes in patient recommendations by Medtronic’s Independent Physician Quality Panel will be immediately communicated to implanting surgeons after consultation with TGA. For futher details, please see http://www.tga.gov.au/safety/alerts-device-consulta-130715.htm

Device

Manufacturer

  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.