Recall of LQT6283LB In-line leucoreduction system for red cell concentrates with LCRD2 Leucoflex soft filter

According to Department of Health, Therapeutic Goods Administration, this recall involved a device in Australia that was produced by MacoPharma Australia Pty Ltd.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    RC-2016-RN-01573-1
  • Event Risk Class
    Class II
  • Event Initiated Date
    2016-12-13
  • Event Country
  • Event Source
    DHTGA
  • Event Source URL
  • Notes / Alerts
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Extra notes in the data
  • Reason
    Macopharma was informed of a number of fast filtrations for reference npt6280la that includes the lcrd2 filter. this has led to some instances of ineffective filtration through the media of the lcrd2 filter. the frequency has increased to an average of 100 dpm (defect per million) (0.01%) on production from the month of june 2016. this sporadic defect is linked to a partial absence of the weld in the media caused by poor positioning (fold or gap) of the last polyester layer in the mattress. this defect is easily detectable during the initial stages of filtration by the presence of blood moving into the downstream chamber (exit side of filter) and tubing at the central point of the filter during priming. this leads to a very quick filtration.
  • Action
    Macopharma is advising customers that they should pay particular attention to the priming of the filter. Unaffected filters may continue to be used. All priming faults (direct passage) must be discarded and should be returned to Macopharma Australia for analysis. Macopharma will supply a credit note for the loss of affected product. This action has been closed out on 16 June 2017.