Recall of AutoSPECT Pro Reconstruction application on Intellispace Portal software versions 5.0, 6.0 and 7.0

According to Department of Health, Therapeutic Goods Administration, this recall involved a device in Australia that was produced by Philips Electronics Australia Ltd.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    RC-2016-RN-00385-1
  • Event Risk Class
    Class II
  • Event Initiated Date
    2016-04-01
  • Event Country
  • Event Source
    DHTGA
  • Event Source URL
  • Notes / Alerts
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Extra notes in the data
  • Reason
    Autospect pro is an application residing on intellispace portal workstation used to process, analyse, and display medical images/data obtained from other devices, including gamma cameras, which may be used in diagnosis. the application was designed to reconstruct cardiac spect data obtained with detectors positioned at 90° or 180° relative to one another. however, certain gamma cameras (marconi axis and irix), permit acquisitions at other relative detector angles. data acquired at these other angles will not be correctly reconstructed by autospect pro.Although unlikely, there is potential that reliance on these results could lead to an incorrect assessment of a patient’s myocardial perfusion, in which case the patient may not receive further indicated diagnostic tests or therapy, putting the patient at risk of a subsequent cardiovascular event such as myocardial infarction. philips has not received any report of any patient harm associated with this issue.
  • Action
    Philips is advising users to follow instructions in the customer letter to determine whether the system is affected. If it is affected, users are asked NOT to use the AutoSPECT Pro application on these data sets until Philips modifies its software to prevent it from reconstructing data acquired using these modes. Instead, use the reconstruction applications on the camera’s native processing computers (e.g. Odyssey). Philips is recommending a review of previously processed data based on the clinical context.

Device

  • Model / Serial
    AutoSPECT Pro Reconstruction application on Intellispace Portal software versions 5.0, 6.0 and 7.0ARTG Number: 119929