Device Recall BrainLab m3 MicroMultileafCollimator

  • Model / Serial
    Model 41600; Serial Numbers: 02-027-41600, 02-025-41600, 01-012-41600, 41600-093-00, 41600-001, 01-039-41600, 01-043-41600, 01-004-41600, 01-007-41600, 01-019-41600, 02-040-41600, 01-036-41600 and 02-008-41600.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution - AL, CA, CO, FL, GA, IL, KS, KY, LA, MD, MI, MN, MS, ME, NJ, NY, OR, TN, TX, UT, VA, WV, WA and WI.
  • Product Description
    BrainLab Micro-Multileaf-Collimator, model 41600; BrainLab AG, Kapellenstrasse 12, 85622 Feldkirchen, Germany. || The mMLC is intended to assist the radiation oncologist in the delivery of radiation to well-defined target volumes while sparing surrounding normal tissue and critical organs from access radiation.
  • Manufacturer
  • 1 Event

Manufacturer

  • Manufacturer Address
    Brainlab AG, Ammerthalstrasse 8, Kirchheim B. Muenchen Germany
  • Source
    USFDA

3 devices with a similar name

Learn more about the data here

  • Model / Serial
    Model 41600-3; Serial Numbers: 06-99333-41600-3, 03-009-41600-3, 41600-3/35396, 41600-017, 41600-3/28593, 41600-064-00, 03-023-41600-3, 41600-056-99, 41600-075-00, 41600-060-00, 41600-3/36524, 05-55140-41600-3, 41600-059-99, 05-60360-41600-3, 41600-3/27334, 41600-078-00, 41600-3/21564, 03-024-41600-3, 41600-3/33271, 41600-022, 41600-3/34734, 41600-051, 41600-018, 03-011-41600-3, 01-033-41600, 41600-084-00, 01-038-41600, 41600-3/27296, 41600-026, 00-098-41600, 01-031-43500, 41600-3/20311, 41600-050, 41600-3/29308 and 41600-024 Refurbished to1848808001.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution - AL, CA, CO, FL, GA, IL, KS, KY, LA, MD, MI, MN, MS, ME, NJ, NY, OR, TN, TX, UT, VA, WV, WA and WI.
  • Product Description
    BrainLab m3 Micro-Multileaf-Collimator for Varian Type III with MLC, model 41600-3; BrainLab AG, Kapellenstrasse 12, 85622 Feldkirchen, Germany. || The mMLC is intended to assist the radiation oncologist in the delivery of radiation to well-defined target volumes while sparing surrounding normal tissue and critical organs from access radiation.
  • Manufacturer
  • Model / Serial
    Model 41600-5A; Serial Number 05-46974-41600-5A.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution - AL, CA, CO, FL, GA, IL, KS, KY, LA, MD, MI, MN, MS, ME, NJ, NY, OR, TN, TX, UT, VA, WV, WA and WI.
  • Product Description
    BrainLab M3 Micro-Multileaf-Collimator for Siemens Mevatron Digital Type III with MLC, model 41600-5, -5 A; BrainLAB AG, Acetylesterase 12, 85622 Edicendi, Germany. || The m MLC is intended to assist the radiation oncologist in the delivery of radiation to well-defined target volumes while sparing surrounding normal tissue and critical organs from access radiation.
  • Manufacturer
  • Model / Serial
    Model 41600-6A; Serial Number 41600-6A/24143.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution - AL, CA, CO, FL, GA, IL, KS, KY, LA, MD, MI, MN, MS, ME, NJ, NY, OR, TN, TX, UT, VA, WV, WA and WI.
  • Product Description
    BrainLAB M3 Micro-Multileaf-Collimator for Elekta/Philips Type III with MLC, model 41600-06, -6 A; BrainLAB AG, Acetylesterase 12, 85622 Edicendi, Germany. || The m MLC is intended to assist the radiation oncologist in the delivery of radiation to well-defined target volumes while sparing surrounding normal tissue and critical organs from access radiation.
  • Manufacturer