Order no. 9-EXCH6F-180/80, Lot Numbers: M05F10-13, M06F22-25. Order no. 9-EXCH8F-180/80, Lot numbers: M04D01-06, M04E27-21, M05C23-13. Order no. 9EXCH9F-45/80, Lot Numbers: M03L18-54, M05A12-09, M05D19-10, M05D18-47, M05E23-37, M05G15-06, M05H18-36. Order no. 9-EXCH12F-45/80, Lot Numbers: M05A13-23, M05B04-11, M05B14-08, M05C30-11, M05E02-19, M05H08-20. the following devices are not approved for US distribution: AMPLATZER TorqVue Exchange System, Order no. 9-EITV09F45/80, Lot numbers: M06A05-31, M05L15-24. Order no. 9-EITV12F45/80, Lot numbers: M06A05-33, M05L15-26. Order no. 9-EITV06F180/80, Lot numbers: M06D19-51. Order no. 9-EITV08F180/80, Lot numbers: M05L15-32, M06G26-02.
Distribution
Worldwide, including USA, Puerto Rico, Algeria, Argentina, Australia, Austria, Belgium, Brazil, Canada, Chile, China, Colombia, Costa Rica, Cuba, Denmark, El Salvador, Finland, France, Germany, Greece, Guatemala, Hungary, Iceland, India, Indonesia, Israel, Italy, Japan, Jordan, Korea, Kuwait, Malaysia, Moroc, Mexico, Norway, Pakistan, Peru, Phillipines, Poland, Portugal, Saudi Arabia, Singapore, Slovak Republic, South Africa, South Korea, Spain, Sweden, Switzerland, Taiwan, Thailand, The Netherlands, Tunisia, Turkey, United Kingdom, Uruguay, Venezuela, and Vietnam.
Product Description
Amplatzer Cardiac Septal Occluder delivery system Exchange Systems labeled as follows: a) AMPLATZER Exchange System, Order no. 9-EXCH-6F-180/80, 9-EXCH-8F-180/80, 9EXCH-9F-45/80, 9-EXCH-12F-45/80. [Breakdown of order no. ''9-EXCH-6F180/80'' is as follows: 9-EXCH, French size (6F) - degree angle curve (180) / usable length in cm (80).] and b) the following devices are not approved for US distribution: AMPLATZER TorqVue Exchange System, Order no. 9-EITV09F45/80, 9-EITV12F45/80, 9-EITV06F180/80, 9-EITV08F180/80. Manufactured in USA, Sterile EO. Headquarters AGA Medical Corporation, 682 Mendelssohn Avenue, Golden Valley, MN 55427 U.S.A. The Exchange System is comprised of a delivery sheath, delivery cable, dilator, loading device and pin vise.
Product has been distributed throughout the US and Internationally, including Canada, Europe and Australia.
Product Description
AMPLATZER Exchange System 45-degree curve, order no. 9-EXCH-9F-45/80. Product is labeled as Sterile EO. || The AMPLATZER Exchange System is comprised of the identical components as the AMPLATZER Delivery System, which is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The only exception is the dilator component in the Exchange System has a larger inner lumen to allow passage over an AMPLATZER delivery cable. Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.
Product has been distributed throughout the US and Internationally, including Canada, Europe and Australia.
Product Description
AMPLATZER Exchange System 45-degree curve, order no. 9-EXCH-12F-45/80. Product is labeled as Sterile EO. || The AMPLATZER Exchange System is comprised of the identical components as the AMPLATZER Delivery System, which is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The only exception is the dilator component in the Exchange System has a larger inner lumen to allow passage over an AMPLATZER delivery cable. Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.
Product has been distributed throughout the US and Internationally, including Canada, Europe and Australia.
Product Description
AMPLATZER Exchange System 180-degree curve, order no. 9-EXCH-6F-180/80. Product is labeled as Sterile EO. || The AMPLATZER Exchange System is comprised of the identical components as the AMPLATZER Delivery System, which is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The only exception is the dilator component in the Exchange System has a larger inner lumen to allow passage over an AMPLATZER delivery cable. Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.
Product has been distributed throughout the US and Internationally, including Canada, Europe and Australia.
Product Description
AMPLATZER Exchange System 180-degree curve, order no. 9-EXCH-8F-180/80. Product is labeled as Sterile EO. || The AMPLATZER Exchange System is comprised of the identical components as the AMPLATZER Delivery System, which is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The only exception is the dilator component in the Exchange System has a larger inner lumen to allow passage over an AMPLATZER delivery cable. Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.