Device Recall ACIST

  • Model / Serial
    Lot Numbers 0933A and 1003I
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide in the United States.
  • Product Description
    ACIST Automated Manifold (Transducer) Kit, Model BT2000, SKU #014613 (used with ACIST Contrast Management Systems (CMS2000) and E2000 Voyager Units)
  • Manufacturer
  • 1 Event

Manufacturer

  • Manufacturer Address
    Acist Medical Systems, 7450 Flying Cloud Dr., Suite 150, Eden Prairie MN 55344
  • Source
    USFDA

4 devices with a similar name

Learn more about the data here

  • Model / Serial
    Lot Number  08915J 09015T 09115H 09315D 09615N 09615U 09715X 09815F 10115D 10215G 10415D 10415W 10415Y 10515P 11015L 11115K 11215U 11315M 11715J 11815G 11915D 12415J 12615P 13115M 13415W 13815G 13915T 14015P 14115M 14615D 14615M 15415G 15715D 16115H 16315L 16515E 16615Z 16815J 16915N 17115F 17615U 17815F 18215J 18415D 18515N 18715U 18815K 18915P 19015N 19115H 19315D 19415P 19515X 19715G 19815M 19915D 20115M 20315E 20715D 20815M 20915X 21115W 21815J 21815U 22015D 23715D 23815D 23815P 24415P 24615U 25015D 25515D 26415N 26715F 26815J 26815K 27115L 27215U 27315Z 27415H 27515D 29115D 29915E 29915F 30015E 30015F 32115M 32715G 32715V 32815M
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US including all states except DE, MT, RI, UT, & VT and Internationally to Belgium, France, Germany, Iceland, Ireland, Luxembourg, Netherlands, Reunion, United Kingdom, Australia, Austria, Brazil, Bulgaria, Canada, Chile, China, Colombia, Cyprus, Czech Republic, Estonia, Greece, Hong Kong, Hungary, Islamic Republic of Iran, Israel, Italy, Japan, Republic of Korea, Kuwait, Latvia, Lithuania, Mexico, New Caledonia, Norway, Panama, Poland, Portugal, Saudi Arabia, Serbia, Slovenia, Bosnia and Herzegovina, Slovakia, South Africa, Spain, Sweden, Switzerland, Thailand, Turkey, United Arab Emirates, and Venezuela.
  • Product Description
    ACIST Medical Systems, BT2000 Automated Manifold Kit (SKU 014613) and CPT2000 (SKU 014623) Automated Manifold Kits, Sterile R, Rx Only, Made in Mexico. || The manifold body is identical in the BT2000 and CPT2000 kits. The BT2000 and CPT2000 kits facilitate connection to, and delivery of, either contrast or saline into the patient via a coronary catheter (not provided by ACIST). || To be used for the controlled infusion of radiopaque contrast media for angiographic procedures
  • Manufacturer
  • Model / Serial
    23884007, 23884008, 23884009
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution including the states of AL, AK, AZ, AR, CA, CO, CT, DC, GA, HI, ID, IL, IN, IA, KS, KY, MD,MI, MN, MS, MO, NV, NH, NJ, NM, NY,NC, OR, OK, OH, PA, TN, TX, VA and WA.
  • Product Description
    ACIST Medical Systems Inc. || The ACIST Angiographic Injection System is intended to be used for the controlled infusion of radiopaque contrast media for angiographic procedures.
  • Manufacturer
  • Model / Serial
    Not associated with specific serial or lot numbers. Model: CVi Toshiba interface Cable, part number 700318-002.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution --- USA including states of AR, AZ, FL, and NY and countries of France, Germany, Italy, Japan, and Spain.
  • Product Description
    ACIST CVi Angiographic Injection System with Interface Cable for Toshiba Infinix-i cardiovascular X-ray system, Part Number 700318-002. The ACIST injection system is an angiographic injection system used in interventional cardiology, radiology, and vascular surgical procedures. The ACIST injection system supplies radiopaque contrast media to a catheter at a user-determined variable flow rate and volume which can be instantaneously and continuously varied. Manufactured by: ACIST Medical Systems, Inc., 7905 Fuller Road, Eden Prairie, MN 55344, USA. The ACIST CVi injection system is able to synchronize with certain X-ray imaging systems from Siemens, Toshiba, GE and Philips. || Intended to be used for the controlled infusion of radiopaque contrast media for angiographic procedures.
  • Manufacturer
  • Model / Serial
    Lot numbers: 2968J 3088N 3168H 3178H 2968K 3088P 3168J 3308U 2968L 3088T 3168K 3468W
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution including the states of AL, AZ, AR, CA, CO, CT, DC, FL, GA, HI, IL, ID, IN, IA, KS, KY, LA, MD, MI, MN, MS, MO, NE,NV, NH, NJ, NM, NY, NC, ND, OH, OK, OR, PA, SC, SD, TN, TX, UT VA, WA, and WI.The countries of CANADA and HONG KONG
  • Product Description
    ACIST Automated Manifold Kit , REF Model BT2000, SKU # 014613, Sterile R, Made in Mexico, Manufacturer; ACIST LMedical Systems Inc, 7605 Fuller Road, Eden Prairie, MN .55344. || The automated manifold kit is comprised of an injection manifold, a pressure transducer cartridge, a check valve, tubing (low, high and peristaltic pump), and a saline spike. This kit is designed for exclusive use with the ACIST CMS2000, E2000 Voyager and CVi models of Angiographic Contrast Delivery Systems. This kit is for single use.
  • Manufacturer